Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Language
Document Type
Year range
1.
Inventions ; 6(4):81, 2021.
Article in English | ProQuest Central | ID: covidwho-1599019

ABSTRACT

Remote monitoring of vital signs in infectious patients minimizes the risks of viral transmissions to healthcare professionals. Donning face masks could reduce the risk of viral transmissions and is currently practiced in medical facilities. An acoustic-sensing device was attached to face masks to assist medical facilities in remotely monitoring patients’ respiration rate and wheeze occurrence. Usability and functionality studies of the modified face mask were evaluated on 16 healthy participants. Participants were blindfolded throughout the data collection process. Respiratory rates of the participants were evaluated for one minute. The wheeze detection algorithm was assessed by playing 176 wheezes and 176 normal breaths through a foam mannequin. No discomfort was reported from the participants who used the modified mask. The mean error of respiratory rate was found to be 2.0 ± 1.3 breath per minute. The overall accuracy of the wheeze detection algorithm was 91.9%. The microphone sensor that was first designed to be chest-worn has been proven versatile to be adopted as a mask attachment. The current findings support and suggest the use of the proposed mask attachment in medical facilities. This application can be especially helpful in managing a sudden influx of patients in the face of a pandemic.

2.
IEEE Sensors Journal ; 2021.
Article in English | Scopus | ID: covidwho-1566246

ABSTRACT

Early diagnosis of pulmonary implications is fundamental for the treatment of several diseases, such as idiopathic pulmonary fibrosis, rheumatoid arthritis, connective tissue diseases and interstitial pneumonia secondary to COVID-19 among the many. Recent studies prove that a wide class of pulmonary diseases can be early detected by auscultation and suitably developed algorithms for the analysis of lung sounds. Indeed, the technical characteristics of sensors have an impact on the quality of the acquired lung sounds. The availability of a fair and quantitative approach to sensors’comparison is a prerequisite for the development of new diagnostic tools. In this work the problem of a fair comparison between sensors for lung sounds is decoupled into two steps. The first part of this study is devoted to the identification of a synthetic material capable of mimicking the acoustic behavior of human soft tissues;this material is then adopted as a reference. In the second part, the standard skin is exploited to quantitatively compare several types of sensors in terms of noise floor and sensitivity. The proposed methodology leads to reproducible results and allows to consider sensors of different nature, e.g. laryngophone, electret microphone, digital MEMS microphone, mechanical phonendoscope and electronic phonendoscope. Finally, the experimental results are interpreted under the new perspective of equivalent sensitivity and some important guidelines for the design of new sensors are provided. These guidelines could represent the starting point for improving the devices for acquisition of lung sounds. IEEE

SELECTION OF CITATIONS
SEARCH DETAIL